ReliaSoft
uses minor version "service releases" to add features and resolve
any issues with the software. These updates are free to registered
users and this page allows you to download the most recent service
release for Xfmea.
We recommend
that you check this Web site occasionally to make sure that you
are always running the most up-to-date version of the software that
is available.
 |
| Current
Version of Xfmea |
 |
 |
|
Compile Release Version |
Build Date |
|
4.0.6 |
8/01/08 |
|
To determine the Compile Release Version (CRV)
of the application on your computer, select
About from the Help menu. |
|
![]() |
![]() |
December
18, 2008: Click
here to download
the Xfmea Standard Hot Fix. For more information about the Hot Fix and why you might need
it, refer to Technical Support Document #
RS20016.
|
|
Prior
Versions |
|
If you have not yet upgraded from
Xfmea 3,
click
here to obtain the last service release for that version
(click here for
Xfmea 2). These versions
have been retired but are still
supported
by ReliaSoft. Click here to review
some of the new and enhanced features in version 4 or
click
here to order the upgrade. |
|
Single-User License |
|
If you have a single-user license for
Xfmea 4, please download
and install the following service release.
|
|
Network License |
|
If you have a network license for
Xfmea 4, please download and install the following
service release on each client computer. NOTE: In
order for the client application to work properly, the current
version of the Network User Management Console must
have been installed on the server by the network administrator.
To download the most recent version of the network console,
click here...
|
|
|
Downloading and Installing Service Releases
To download the installation program, right-click the link
and select Save Target As (or the equivalent command
for your browser) from the shortcut menu.
Remember to close all other applications before running
the installation.
Contact ReliaSoft's
Technical
Support Engineers with questions or concerns.
|
|
| |
|
Modifications
and Enhancements to Xfmea 4 |
|
The
modifications/enhancements for each service release are described
next. This information is also available in the ReadMe file
that is installed with the software. The
most recent service release (build) contains all previous modifications.
Build
4.0.6
Modifications
- Incorporated French translations for the interface and library data. To select the French
interface, go to the Other page of the User Setup.
Build
4.0. 5 Modifications
- Added a warning that appears when the user selects the Synch option in the Control Plan or the DVP&R window.
- Addressed an issue with the
Cause page in the Query Utility, where the SxO value
was not displayed in the results if a Detection
rating had not been assigned.
- Addressed an issue with the
ability to filter by Action Status in the Filtered
View for actions.
- Added the ability to copy
the visible portion of the FMEA Hierarchy or System
Hierarchy as a graphic that can be pasted into
another document. Select one of the Copy Panel as
Graphic commands from the Edit menu.
- Added the ability within
the Worksheet View to enter data for a lower-level
record without first creating the higher-level
record(s) that it will be associated with. For
example, if you type the Cause description in a row
that does not yet have an Effect defined, the
software will now allow you to type the Cause
description and will enter a placeholder
("<undefined>") for the associated Effect record.
Build
4.0.4 Modifications
- Added Report Customization
features to the Report Generation window. This
functionality is currently available for the
Standard and Comprehensive styles of the FMEA
Spreadsheet, the Control Plan, the DVP&R and the
DRBFM reports. Click the Customization/Settings
button in the Report Generation window.
- The Reports page has been
removed from the User Setup. These options are now
available on the Settings page of the Report
Customization/Settings window.
- Added the ability to
specify the font style and size that will be used
for print-ready reports. Report
Customization/Settings: Settings.
- Added the option to display
two columns for Control records in the Worksheet
View, the Standard FMEA Spreadsheet report and the
Comprehensive FMEA Spreadsheet report. User Setup:
Other.
- Added the option to display
the control type and the control description in the
same column in a Standard or Comprehensive FMEA
Spreadsheet report when the One Column option is
selected on the Other page in User Setup (i.e.
provides a display similar to the SAE J1739 format
when using the more customizable Standard or
Comprehensive report styles). Report
Customization/Settings: Settings.
- Added the option to
generate DRBFM reports from the Report Generation
window, in addition to the existing ability to
generate the report directly from the DRBFM window.
- When the Control Plan, DVP&R
or DRBFM reports are generated from the Report
Generation window, the user now has the option to
include sub-items in the same table as the parent
item.
- Added the ability to
generate FMEA Spreadsheet reports in which each row
contains all FMEA information related to that row,
even if some of the information is repeated from the
row above and would otherwise have been "merged"
within the table. This allows the spreadsheet report
to be sorted in Excel, if desired.
- Modified the AIAG and J1739
import templates (ImportSpreadsheet_AIAG.xls and
ImportSpreadsheet_J1739.xls) so that the software is
now capable of importing the Target Completion Date
via a separate column at the end of the spreadsheet.
- Modified the Associated
FMEA Records window to display the full descriptions
for all related records. When accessed from the
Controls Manager, this utility displays the Actions,
if any, that have been defined for the same Cause.
When accessed from the Actions Manager, it displays
the Controls.
- Modified the Quantitative
Criticality Analysis calculation method to allow
analysts to define the failure behavior more
realistically (e.g. with a Weibull or lognormal
distribution) but still return results identical to
the original MIL-STD calculation method if all items
have been defined with a constant failure rate
(exponential distribution). Mode Criticality =
Expected Failures x Mode Ratio of Unreliability x
Probability of Loss.
- The Copy Existing command
is now accessible directly from cells within the
FMEA Worksheet View.
- Made minor modifications to
the Help menu and Project toolbar.
- Updated the integration
with Weibull++ and ALTA to support the latest
released versions of those products.
- Translated the interface
and library data to Spanish. User Setup: Other.
Build
4.0.3 Modifications
- Addressed an issue with RPN
calculations that was introduced in Build 4.0.2 and
occurred only when the user copy/pasted a Function
that had Causes with calculated RPNs. This service
release prevents the issue from recurring in the
future. To update the RPN calculations for existing
databases, use the "Compact and Repair Database"
feature (select Database Tools from the
Tools menu and then click Compact and Repair
Database).
Build 4.0.2
Modifications
- Addressed an issue with saving the calculated RPN when data
were entered in a specific sequence.
- Addressed some issues with FMEA import templates when used
under specific conditions.
- Added support for the new FMEA Accelerator® Template
Collection, which allows you to purchase "generic" FMEA
templates for different types of components/equipment and
import the valuable engineering knowledge into your own
projects.
- Added the ability to import Control Plan, DVP&R and/or DRBFM
data from Excel. (The required templates are installed in
the "Examples" folder of the application directory, e.g.
C:\Program Files\ReliaSoft\RCM4\Examples.)
- Added the option to automatically spell-check an entire
analysis displayed in the Worksheet view. (With the
Worksheet view displayed, select "Spell Check Worksheet"
from the "Edit" menu.)
- Added new report forms to the Report Generator: Analysis
Plan Details, FMEA Spreadsheet: VDA-86, FMEA Spreadsheet:
VDA-96, and VDA Action Tracking.
- Added the ability to automatically remove Login Security
from a database. (Select "Administrative Options" from the
"Tools" menu. After supplying the administrative login,
click "Remove Login Security.")
- Improved the software's performance when transferring large
amounts of data (e.g. import items from Excel, copy/paste,
etc.).
- In the Transfer Project window, added the option to transfer
records as "<undefined>." For example, this allows you to
transfer the Causes and Failures from the DFMEA but leave
the PFMEA Functions undefined.
- Added the option to delete an Analysis Plan. (Open the
Analysis Plan window and click "Delete Plan."
- Added the option to exclude specified Actions from the query
results, graphical charts and reports. For example, if you
create Actions called <None> to indicate that no corrective
actions will be performed, these Actions can be excluded
from Actions lists and charts that are generated by the
software. (Set this via the Other page of the User Setup.)
- Added the option to set the Active Library from within the
Profiles/Libraries Manager window (in addition to the Other
page of the User Setup).
- Added the option to transfer specified Actions to the DVP&R
upon Synch. (On the Settings(1) page of the User Setup,
select "Transfer Controls and Actions" and specify one or
more Action Categories (separated by semi-colons) to
identify the types of records that will be transferred. For
example, if you type "Testing; Verification" then any
Actions that have been assigned to the "Testing" or
"Verification" Action Categories will be transferred when
you synchronize the FMEA/DVP&R.)
- Added the option to generate reports to a document that has
"Page Setup" options configured specifically for A4 paper.
(Select "A4" on the Reports page of the User Setup).
- Added the option to set generated report files as
"Read-Only." (Set from the Reports page of the User Setup.)
- Modified the automatically generated Process Flow Diagrams
to include information from more levels in the System
Hierarchy, if applicable.
- Modified the automatically generated Item Cause and Effect
Diagrams to include the "Effect" descriptions from the FMEA.
- Added the "Use Tabs" option to the Windows menu.
- Modified the way Phrase Sets are maintained in the
Profiles/Libraries Manager. Duplicate descriptions will be
removed upon Save.
- Translated the interface and library data to Portuguese.
(Set from the Other page of the User Setup.)
- Added "Attachments" command to the shortcut menu that
appears when you right-click a cell in the Worksheet View.
This opens the Links/Attachments window for the current
record.
- Addressed an issue with inserting rows into Control Plans
and DVP&Rs.
- Adjusted the No. column in the Control Plan so that
numerical data such as 01-06 will appear as a number instead
of a date when the data is exported to Excel.
Build 4.0.1
Modifications
- Initial Release. Modifications/enhancements
from Version 3 include:
- Added a "Change Log" utility.
Authorized users can select "Activate Change Log" from
the System Hierarchy menu or shortcut menu to activate
the log. All users can select "View Change Log" from
the System Hierarchy menu or shortcut menu to view the
recorded changes for an item that has an active Change
Log.
- Added a Design Review Based
on Failure Mode (DRBFM) utility. Select "Attachments"
then "Open DRBFM" from the System Hierarchy menu or
shortcut menu.
- Added a "Display in Worksheet"
field for the Action Person Responsible. This will allow
users to type the information for the "Responsibility"
column directly in the worksheet instead of using the
"Person Responsible" window.
- Added customizable "tooltips"
to the column headers for the FMEA, Control Plan, DVP&R
and DRBFM worksheets. Select "Show tooltips for worksheet
columns" from the Settings(2) page of the User Setup
to turn on the tips. To edit the tips, use Notepad to
the edit the "_Tooltips.txt" files in the application
directory (e.g. C:\Program Files\ReliaSoft\RCM\FMEASheet_Tooltips.txt).
- Added two new profiles to the
default Library that can be used to configure the software
to fit the VDA-Volume 4 guidelines used by the German
automotive industry.
- Added the option to choose
"Export As Fault Tree" when exporting a project to an
XML file that can be opened by BlockSim.
- Added the option to assign
separate rating scales in the same project for the Severity
rating used to calculate an RPN and the "Severity Class"
used for Criticality Analysis; likewise for the Occurrence
rating used to calculate an RPN and the "Failure Probability"
used for Criticality Analysis.
- Added the ability to query
Actions by individual Severity, Occurrence or Detection
ratings of the associated Effect and Cause.
- Added the ability to query
Controls by the RPN or SxO of the associated Cause.
- The large "Copy Existing" button
in each Properties window has been replaced with a smaller
icon. The functionality is the same.
- The software now "remembers"
your preference for the position of the columns in the
System Hierarchy and FMEA Hierarchy panels.
- Redesigned the Setup Wizard
to present a more streamlined selection of the most
important settings.
- Added the option to specify
the "Port" for the SMTP Server that is used for automated
e-mail notifications.
- Modified the design of the
Probability tab for the Cause Properties window to try
to make it clear that the time value on the right side
of the window is not stored with the record or used
for automated calculations. This feature allows you
to calculate the probability "on the fly" for any time
value based on the distribution and parameter(s) that
you have specified.
- Enhanced the Analysis Plan
window to work more intuitively. The % Completion is
now updated automatically on the Analysis Checklist
page and the Attendance feature on the Work Sessions
page now displays all team members, even if the record
has not been saved since new team members were added.
- Added an option to the Descriptions
page of the User Setup (and the Options page of the
Select Existing window) called "Show only unique." When
this option is selected, then the Select Existing, Bulk
Add and Copy Existing utilities include 1 row for each
unique description (or set of properties), even if it
occurs multiple times. However, the descriptions will
be truncated to 255 characters only. When the option
is not selected, the descriptions are not truncated
(e.g. the full 1000 character Cause description can
be copied) but there will be a separate row for each
instance.
- Control #s have been changed
to work the same way as Action #s. There is a new option
called "Autonumber new Controls" on the Settings(2)
page of the User Setup and a new command in the File
menu called "Renumber Controls."
- The date when a project was
created is now stored in the database. In Login Secure
databases, the name of the creator is also stored.
- Addressed an issue with generating
the Occurrence/Severity Matrix chart when the data set
contains a very large number of Causes.
|
|
|